Título: Análise, verificação e recuperação de pórticos de concreto armado afetados por corrosão das armaduras
Orientador(es): Daniel Andrade Mota
Palavras-chave: Patologia - Engenharia Civil
Estruturas de Concreto
Corrosão
Data do documento: 2023
Editor: Centro Universitário Maria Milza
Membros da Banca : Felipe Silva dos Santos
Jessica Oliveira Reis
Resumo: A subestação de Sapeaçu, local onde se desenvolveu o estudo de caso, está localizada na fazenda touro s/nº, BR101 km 232, Sapeaçu BA. O local a qual está inserido, possui características bastante comuns a um microambiente rural, com temperatura ambiente médias de 26,33ºC, e umidade média do ar de 72,7%. A equipe de manutenção da subestação na sua rotina de atividades, realiza inspeções preventivas e identificou pequenas fissuras nas estruturas portantes dos equipamentos elétricos. Após identificadas as manifestações patológicas causadas pela penetração de agentes externos, principalmente água e oxigênio nas armaduras, através das fissuras, descreveu-se uma metodologia com técnicas simples de recuperação e diagnóstico prévio com detalhes do estado de deterioração das armaduras, e constatada necessidade de recuperação, assim tivemos que definir qual metodologia deve ser aplicada na recuperação das estruturas de concreto prémoldado em subestação energizada. A escolha da recuperação como estudo, é que um dos integrantes da equipe trabalha no local, e identificou a oportunidade de estudar o caso. Após identificado que a corrosão nas armaduras das estruturas esta uniforme e generalizada em toda a armadura, além de perder capacidade portante por expandir-se, já que esses compostos possuem volume cerca de sete vezes maior que o volume da armadura na forma de barra. Com base em análise dos ensaios realizados, a longevidade e a necessária prevista, a recuperação a ser desenvolvida, será recuperação estrutural tradicional com a substituição de todo o concreto contaminado, e adição do sistema de proteção catódica simples e o concreto carbonatado, será substituído por graute de base cimentícia com resistência característica mínima e boa aderência ao concreto antigo. O estudo visa embasamento técnico e direcionamento a todos os empreendimentos que sofram com este tipo de corrosão em regiões com características parecidas as apresentadas no estudo, com intuito de diminuir o tempo de análise das patologias e a assertividade no tipo de recuperação a ser implementada. _______________________________________________________________________________________ ABSTRACT The Sapeaçu substation, where the case study was developed, is located at the Touro S/nº farm, BR101 km 232, Sapeaçu BA. The place in which it is located has characteristics quite common to a rural microenvironment, with an average ambient temperature of 26.33ºC, and an average humidity of 72.7%. The maintenance team of the substation, in its routine activities, carries out preventive inspections and identified small cracks in the load-bearing structures of the electrical equipment. After identifying the pathological manifestations caused by the penetration of external agents, mainly water and oxygen in the reinforcement, through the cracks, a methodology with simple recovery techniques and previous diagnosis with details of the state of deterioration of the reinforcement was described, and the need for recovery was verified, so we had to define which methodology should be applied in the recovery of precast concrete structures in energized substation. The choice of recovery as a study is that one of the team members works at the site, and has identified the opportunity to study the case. After identifying that the corrosion in the reinforcement of the structures is uniform and generalized throughout the reinforcement, in addition to losing load-bearing capacity due to expansion, since these compounds have a volume about seven times greater than the volume of the reinforcement in the form of a bar. Based on the analysis of the tests carried out, the longevity and the necessary foreseen, the recovery to be developed, will be traditional structural recovery with the replacement of all contaminated concrete, and the addition of the simple cathodic protection system and the carbonated concrete, will be replaced by cement-based grout with minimum characteristic resistance of adhesion to the old concrete. The study aims to provide a technical basis and guidance to all enterprises that suffer from this type of corrosion in regions with characteristics similar to those presented in the study, in order to reduce the time of analysis of pathologies and the assertiveness in the type of recovery to be implemented.
URI: http://131.0.244.66:8082/jspui/handle/123456789/3050
Aparece nas coleções:UNIMAM - Trabalho de conclusão de curso

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ENGENHARIA CIVIL - LUAN, IRLAN E ROBERTO.pdf1,88 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.